6. Product information
6.4 Technical specifications
M=Medium
S=Standard
P= Internal controller
1= Version 1 (1,000 N; 18 mm/s)
2= Version 2 (2,000 N; 12 mm/s)
3= Version 3 (3,000 N; 8 mm/s)
Version
Installation dimension
Standard lifting length
Weight AC Medium
Weight AC Large
Supply voltage:
Protection class
Lifting speed
Lifting force
Max. power consumption
(primary)
Duty cycle
Max. power consumption
Operating temperature (min./
max.)
Torque load (static)
Version, medium
Torque load (static)
Version, position
M= 200 Nm
M= 450 Nm
52
ACXX n.n/n.n.R n n n
L=Large
AC _ _ 1 _ _ _ ___
18 mm/s
1,000 N
(2 minutes operating time with 8 minutes operating t
F
= 1,000 N / 2,000 N / 3,000 N
Pressurek
F
= 1,000 N / 2,000 N / 3,000 N
Tension
Consecutive number
Accessories:
0= without
1= Pulse generator (Hall-IC)
2= Potentiometer
Installation height (mm)
Lift (mm
AC _ _ 2 _ _ _ ___
Lifting range + 120 mm
200 - 700 mm
6.5 - 15.0 kg
10.0 - 23.5 kg
selectively 36(24) VDC or 230(115) VAC
IP 30
12 mm/s
2,000 N
4.5 A at U= 24VDC
3.5 A at U= 36VDC
0.7 A at U= 230VAC
S3 / 20 % for 10 minutes
According to details on the name plate
-20° Celsius / +60° Celsius
approx. Mmax.= 200 Nm
approx. Mmax.= 450 Nm
AC _ _ 3 _ _ _ ___
8 mm/s
3,000 N