7. Life phases

7.3.3 Parallel alignment

If the lifting columns are not parallel to each other, then the
distance between the top fastening points changes during
motion. However, a rigid connection keeps this distance
constant. The consequence is that considerable forces act on
the lifting column guide, which can be damaged by this.
In this case, the lifting columns should also be aligned exact-
ly. Uneven floors can be compensated by using an adjustable
baseplate.

7.3.4 Bends in the table frames

Table frames are generally made of welded steel tubes and
connection plates for connecting to the lifting columns. If
the connecting plates are not flat against the lifting column,
then the synchro system is stressed during screwing. This
generates unwanted transverse forces which stress the lif-
ting column guide. Please ensure that the components are
working perfectly.
Use the RK SyncFlex compensation plate to compensate the height difference of two
or more lifting columns.
Information on use and technical details of this article can be obtained from the pro-
duct catalogue.