OPERATION
TROUBLESHOOTING
PROBLEM
Poor pick up.
p
p
Vacuum motor does not
operate.
t
Discharge pump does not
g p
p
operate.
t
Discharge pump operates
continuously.
SPECIFICATIONS
Model
LENGTH
WIDTH
HEIGHT
WEIGHT
RECOVERY TANK CAPACITY
VACUUM HOSE
DISCHARGE HOSE
FLOOR WAND WIDTH
DISCHARGE PUMP
DISCHARGE PUMP FLOW RATE
VACUUM MOTOR
SEALED WATER LIFT
POWER CORD LENGTH
TOTAL POWER CONSUMPTION
DECIBEL RATING AT OPERATOR'S EAR, INDOORS ON CARPET
8
CAUSE
Float shut-off screen is clogged.
Loose drain hose knob.
Loose recovery tank cover.
Damaged hose.
Unplugged cord.
Faulty switch or loose wiring.
Tripped building circuit breaker.
Defective vacuum motor.
Unplugged cord.
Faulty pump float switch.
Tripped building circuit breaker.
Defective vacuum motor.
Airlock has formed in discharge pump
inlet.
Faulty pump float switch.
Home
Find... Go To..
SOLUTION
Clean screen inside recovery tank.
Close drain valve.
Tighten down cover with latches.
Replace hose.
Plug cords into separate grounded circuits.
Contact Service Center.
Reset circuit breaker.
Contact Service Center.
Plug cords into separate grounded circuits.
Contact Service Center.
Reset circuit breaker.
Contact Service Center.
Connect open end of discharge hose to
vacuum intake hose connector and turn on
machine.
Contact Service Center.
Tennant 900
762 mm (30 in)
508 mm (20 in)
889 mm (35 in)
41 Kg (90 lbs)
60.5 L (16 gal)
4.5 m (15 ft) x 38 mm (1.5 in)
7.6 m (25 ft) x 38 mm (1.5 in)
330 mm (13 in)
115 volt, 1/3 hp, 8.7 psi/.6 bar, 10 amp
113 L (30 gal) per minute
120 volt, 3--stage, 1.6 hp, 10.7 amp,1242 watts
3048 mm (120 in)
15 m (50 ft)
120V, 17 A, 2040 W (Use Separate Circuits)
80dB(A)
Tennant 900 (02- -06)