Installation - Flotec FP5500 Serie Manual Del Usuario

Bombas centrífugas
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation

KEY
A - Pump Discharge
B - Priming Plug
C - Street El
D - Tee
Figure 1
PIPING
Both suction and discharge piping should be indepen-
dently supported at a point near the pump to avoid
strains being placed on the pump. Start all piping at
pump to avoid strains left by a gap.
It is advisable to increase the size of both suction and
discharge piping at the pump if any appreciable run of
pipe is required. Never use a smaller suction pipe than
the suction connection on the pump. Use a pipe wrench
to hold the suction and discharge bosses of the pump
while making up the piping, to avoid putting excess
strain on the pump.
SUCTION PIPE
The suction pipe must be kept free from air leaks. Any
horizontal run of suction piping must have a gradual
upslope towards the pump. Avoid any fittings which
may cause an air trap. A foot valve should be installed
to prevent loss of pump prime.
DISCHARGE PIPING
A gate valve and union should be installed in the dis-
charge line. For removal of the pump for service, close
the gate valve, and disconnect the union.
PRIMING THE PUMP
Prime pump by filling both the pump and suction line
completely with water thru the priming tee. Replace
Model
HP
Voltage
FP5512
1/2
115/230
FP5522
3/4
115/230
FP5532
1
115/230
FP5542
1-1/2
115/230
FP5552
2
230
For parts or assistance, call Flotec Customer Service at
PERFORMANCE
Inlet
Discharge
25
1-1/4"
1"
22
1-1/4"
1"
31
1-1/4"
1"
47
1-1/4"
1"
59
1-1/2"
1-1/4"
68
priming plug and start pump. If water is not pumped
immediately it is because all the air has not been evacu-
ated. Stop pump and reprime, following instructions
above. When used with vertical discharge, the vent plug
at the top should be loosened to evacuate air which is
trapped inside the volute. When volute is completely
filled with water, tighten vent plug.
NEVER run pump dry. Running pump
without water may cause pump to overheat, damaging
seal and possibly causing burns to persons handling
pump. Fill pump with water before starting.
NEVER run pump against closed dis-
charge. To do so can boil water inside pump, causing
hazardous pressure in unit, risk of explosion and possi-
bly scalding persons handling pump.
Motor normally operates at high tempera-
ture and will be too hot to touch. It is protected from
heat damage during operation by an automatic internal
cutoff switch. Before handling pump or motor, stop
motor and allow it to cool for 20 minutes.
KEY
E - Pump Discharge
J - Base
F - Gate Valve
K - Solid, level
G -Priming Plug
foundation
H - Union
L - Suction Piping
I - Tee
M -Foot Valve
Figure 2
Performance in GPM at Discharge Pressure Shown
30
35
40
45
13
2
25
21
13
40
35
29
17
52
47
40
30
62
54
48
38
1-800-365-6832
4
50
55
Max PSI
36
43
49
15
51
29
7
57

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido