Edit FILLING data:

Use the arrows ↓↑ to select FILLING and press ENTER. The following screen is displayed:
1) Use keys 0 to 9 to enter the quantity (in grams) of refrigerant to be charged into the A/C
system and press ENTER.
NOTE: For most systems the quantity of fluid to be refilled is indicated on a plate that is in
the vehicle's engine compartment. If this quantity is not known, look for it in the relavant
manuals.
2) If installed, you can use DATABASE BASIC (DBB): Use the arrows ↓↑ to select the second
line and press ENTER. The following screen is displayed:
Use the relevant "table" to read off the code for the vehicle. Use the numerical keypad to
key in the code. Once the setting has been completed, press ENTER to confirm. If you
wish to install DATABASE BASIC (DBB) contact the machine dealer.
3) If installed, you can use DATABASE ADVANCED (DBA): Use the arrow ↓ to select the
second line and press ENTER. The following screen is displayed:
Use the arrow keys (↓↑) to move to the brand of vehicle you are servicing, press ENTER to
confirm, and the display will show the models for that type (for example, if you have chosen
FORD):
Use the arrow keys (↓↑) to go to the model required, and press ENTER to confirm. If you
wish to install DATABASE ADVANCED (DBA) contact the machine dealer.
Once you have checked that the data displayed is correct, you can push START to run the
AUTOMATIC PROCEDURE.
The following screen is displayed:
Open the high and low pressure taps on the machine and press the START key to begin the
refrigerant
recovery/recycling
"Recovery/Recycling". During this phase, the LCD will display the quantity of refrigerant
recovered, in grams. Upon completion of recovery, the machine will stop and automatically
INSTRUCTIONS MANUAL
AUTOMATIC PROCEDURE
FILLING
<xxxg>
DATABASE
ENTER CODE
VEHICLE MODEL
...
press ENTER to exit
<ALFA ROMEO>
AUDI
BMW
CHRYSLER/JEEP
<COUGAR>
ESCORT
ESCORT D
FIESTA
Open high and low
pressure, then Press START
phase,
which
-12-
will
be
signaled
on
the
LCD
as