2. Recommendations
Please comply with the following values for your
chlorinator to work properly:
Recommended
Salt
concentration
Minimum
pH
Recommended
Recommended
TAC
between
Stabilizer
Recommended
Water
Do not operate when water is
temperature
colder than15°C.
Chlorine
Between 0,5 and 2,5 ppm
concentration
220
volts-50/60
Connection
controlled
pump.

3. Installing the Y chamber

This cell fits to all standard Ø63 mm drainage
pipes.
Place the tip of the electrode cell downwards.
The electrode may be installed in both flow
directions.
Leave enough space on the removable side of the
cell so that the electrode can be taken out.
4,0 g/l
3,5 g/l
from 7,0 to 7,4
12 and 18 ° F
from 20 to 50
g/m3
Hz
servo-
by
the filtration
101449 Installation and user manual
For the electrolysis chamber to work correctly, it is
recommended that the heating system be placed
within 20 m. of the pool (40 m. of back / forth
piping).
For longer distances, we recommend that you
integrate a relay pump upstream from the heating
system.

4. Electrical connections

4.1 Installing the unit

Fix the unit to a wall of the plant room using the
installation holes at each corner and the screws
and plugs provided.
PRECAUTIONARY MEASURE:
We strongly recommend that the unit be
installed in a sheltered place.

4.2 Unit power supply

Connection: 230 volts - 50/60 Hz
P. max: 70 W
The system must work at the same time as the
filtration pump.
The connection is then made to the filtration
pump's contactor via a 4A fuse box.
A chlorinator that is directly connected to a 230
VAC power supply could damage the components
of the hydraulic circuit and will not be covered by
the warranty.
4.3 Salt electrode power supply
Connect the cable intended for this use. Correctly
tighten the nuts. A poorly-tightened connection can
result in overheating.
Beyond the length of cable supplied with the
machine, the cable section should be sufficient,
13