1
List of parameters
.04
2
250
251
252
256
257
258
263
268
269
271
272
287
288
Presser foot lowering speed
Presser foot clearance when raising
presser foot with automatic presser foot lift
Presser foot clearance when raising
pressure foot with knee switch
Constant presser foot pressure before
sewing
Constant spring pressure during the feed
phase
Machine class
I = 1051 and 1181
II = 1053 and 1183
Display on control panel
I = on
II = off
Beginning of the presser foot pressure
(on the 1051 and 1181)
Beginning of the presser foot pressure
(on the 1053 and 1183)
Presser foot pressure dependent on speed
Presser foot pressure dependent on speed
Clearance under presser foot when
raised by pedal (pedal position –1)
Presser foot pressure (pedal position 0)
When function key F5 is activated, the parameters 271 and 272 can be
requested with the function keys F2 and F3.
For more information and displays see the motor instruction manual.
B, C
0 - 255
B, C
0 – 255
B, C
0 – 255
B, C
0 – 32
B, C
0 – 90
B, C
B, C
I - II
C
0 – 126
C
0 – 126
B, C
0 – 60
B, C
0 – 60
B, C
0 - 255
B, C
0 - 255
GB
5
190
150
10
60
II
I
12
81
20
20
150
80
7