Cleaning The Sprayer; Nozzle Replacement; Storing The Sprayer - Ryobi PSP02 Manual Del Operador

Ocultar thumbs Ver también para PSP02:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

CLEANING THE SPRAYER:

 Fill the tank about one-third full with clean water.
NOTE: Never use flammable chemicals or abrasive
cleaning agents to clean the tank.
 Review chemical SDS sheet how best to secure and store
your chemical solution when not in use.
 Replace the tank cap and tighten securely.
 Reinstall the battery pack. Spray until the tank has been
emptied. Make sure to direct the spray toward an area
that will not be damaged by the spray solution.
 Refill and repeat the procedure with clean water. It may
be necessary to rinse the tank more than once, then drain
again as directed above.
 Allow all pieces to completely dry, then reinstall the tank
cap.
 Wipe the outside of the sprayer with a clean, dry cloth.
NOZZLE MAINTENANCE
See Figures 11 - 12, page 14.
Irregular mist patterns or leakage may be the result of a
clogged or dirty nozzle. To clean nozzles:
 Remove the battery pack.
 Rotate mode selector so that the nozzle is in the 6:00
position.
 Unscrew and remove the nozzle and o-ring from nozzle
holder.
NOTE: Never point the sprayer at your face.
 Using a fine needle, free any foreign materials clogging
or restricting the nozzle.
 Using a garden hose, flush debris out of nozzle by back
flushing (running the water through the nozzle backwards
or from the outside to the inside).
NOTE: If blockage persists, use a screwdriver to remove
the screw and cone from the nozzle. Soak the nozzle,
cone and the screw in warm, soapy water then blow out
the nozzle with pressurized air to remove blockage. After
NOTE: ILLUSTRATIONS START ON PAGE 13 AFTER
FRENCH AND SPANISH LANGUAGE SECTIONS.
MAINTENANCE
 Reinstall the nozzle and o-ring.
When not properly cleaned, the sprayer nozzle may develop
residual chemical build up. This could result in decreased
pressure and spray patterns.
To reduce the chance of blockage, spray a tank of water
through the unit after each use to rinse out any residual
chemical build up that may have occurred.

NOZZLE REPLACEMENT

Use replacement 50 micron nozzles (p/n 316869001), 75
micron nozzles (p/n 316971001) and 100 micron nozzles
(316972001) when replacing worn nozzles.
 Unscrew and remove the old nozzle and o-ring from nozzle
 Turning clockwise, install new and o-ring into the nozzle

STORING THE SPRAYER

 Remove the battery pack from the sprayer before storing.
 Empty all fluid from the tank as described previously in
 Store indoors in a place that is inaccessible to children.
 Keep away from corrosive agents such as garden chemi-
 Store in an upright position.
11 – English
the nozzle is clean, reinstall the cone and screw. When
reinstalling, ensure the cone is seated at the bottom of
the nozzle before screw is installed.
NOTE: It may be necessary to soak the nozzle in vinegar
overnight. Do not soak the o-ring seal.
NOTE: Make sure the nozzle is securely in place before
using.
holder.
holder.
NOTE: Each new nozzle includes an o-ring. If an o-ring
has been removed, replace it before installing the new
nozzle.
Cleaning the Unit.
cals and de-icing salts.

Publicidad

Tabla de contenido
loading

Tabla de contenido