electrical fields, fast supply transients in bursts,
electrostatic discharge and supply surges).
17) Your dealer carries stocks of all spare parts that you might
need. Used batteries must be competend disposed.
18) For use only by dental professionals.
19) When you need to transport the unit, unscrew the
battery and protect the light guide against impacts.
20) For long-term storage we recommend that you
remove the battery from the unit body so that it
does not discharge slowly and risk damage.
21) When your unit reaches the end of its life, we
recommend that you contact your dental equipment
dealer to find out what procedure is advised.
2 - PRESENTATION
The C
2 produces a visible blue light between a
ELALUX
wavelength of 420 and 480 nm for the photo-
polymerization of dental materials. After checking the
packaging for damage (please retain the packaging), you
will find the following:
- the handpiece, fitted with a protective cap,
incorporating the light-emitting diode,
- the base station for recharging the unit, with a built-
in radiometer,
- the power adapter (EU,UK,US),
- the lithium ion battery,
- the multifibre light guide, 45° curvature, Ø7.5mm,
sterilizable,
- the protective light shield,
- the Operating Manual.
3 - INSTALLATION
1- Prior to each use, sterilize the light guide and
disinfect both base station and handpiece (see also
the chapter on care).
2- Screw the battery onto the handpiece, insert the
sterilized light guide into the handpiece. Ensure that
the light guide is inserted correctly (the friction
contact makes a click).
Caution: To insert and extract the light guide from the
handpiece, push/pull and rotate along the axis.
3- Place the base station on a stable surface. Prepare
the power plug in accordance with the main network
used in your country. Plug in the mains adapter and
ensure that the plug is suitable for the voltage of
your power supply. The green light will flash twice.
4- Place the handpiece on its base station (there will be
an audible beep each time the lamp is put in the base)
and leave it to charge for at least 2 hours 30 minutes,
to make sure that the battery is fully charged.
5- The green light starts to flash indicating that the
battery is being charged. As soon as the battery is
fully charged, the light stops flashing and stays lit.
4 - PRODUCT DESCRIPTION
Now that the C
ELALUX
familiarize yourself with its buttons and menus:
2
Handpiece (1)
a) LED indicators:
The handpiece has four LED indicators:
- One LED located at the top, next to the light guide,
indicates the status:
Color
Green
Red
Red flashing
- A row of three LEDs indicates the curing mode
selected.
Symbol
b) Buttons
The handpiece has two buttons:
- one navigation button which is used to switch from one
5
2 is fully charged, you need to
1
Mode
Normal mode
Power supply problem/battery low
Thermal protection
Mode
Fast 10 or 20 s
Soft Start 40 s