5. Installation
5.1 Safety notes
for installation
5.2 Installation
description
5.3 Function test
WARNING
Risk of fatality due to lack of emergency opening facility!
If the product is installed without an emergency opening facility, it may not be
possible to open the door from the outside in the event of fault. If emergencies
occur inside the room during the fault, rescue work will be hindered.
> The operator must ensure that doors to which this product is fitted have
an emergency opening facility in the event of faults.
> Häfele is not liable for damage that is attributable to failure to install an
emergency opening facility.
WARNING
Risk of fatality due to failures or faults in electromagnetically sensitive
devices!
The electromagnetic radiation of the product can cause faults in sensitive parts
(e.g. in medical equipment).
The functionality thereof will be adversely affected.
> Do not place product close to electromagnetically sensitive devices.
> Pay attention to the safety instructions for the electromagnetically sen-
sitive devices.
> If you have any doubts regarding compatibility, please contact the
manufacturer.
NOTE
Damage to product due to incorrect installation!
> Adhere to installation requirements.
> Do not trap or damage wires during installation.
> Never start up and use the product if any wires have been damaged.
> Always drill holes in the door leaf from both sides to prevent pieces of
the door from breaking away.
The installation is described in pictures.
For step-by-step "Installation instructions", see picture
section starting on page 76.
After completing installation, perform a manual function test.
Push the lever handle at the inside of the door:
Correct result:
• Latch bolt is pulled back (escape function).
• Door can always be opened.
Push the lever handle at the outside of the door:
Correct result:
• The lever handle is blocked. The door cannot be opened.
If this is not the case, check the individual installation steps.
21