Product Registration Card - WAGNER CONTROL SPREY HVLP Manual Del Propietário

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

You should inspect the air filter in the turbine to see if it
is excessively dirty. If it is dirty, follow the steps below
to replace it.
1. Insert a straight-slot
screwdriver through
one of the slots in the
rear of the turbine.
2. Pry the filter cover
from the turbine.
Problem
A. Little or no material flow
B. Material leaking
C. Atomization is too coarse
D. Spray jet pulsates
E. Pattern runs or sags
F. Too much overspray
G. Pattern is very light and
splotchy.
Have you tried the recommendations above and are still having problems? In the United States, to speak to a
customer service representative, call our Customer Service at 1-800-328-8251 Monday through Friday between 8:00
AM and 4:30 PM Central time.

Product Registration Card

Send in your product registration card or register online at www.wagnerspraytech.com. Proper registration will serve as proof of
purchase in the event your original receipt becomes misplaced or lost. Returning this card will expedite the processing of your warranty.
Be sure you write your unit's date code on the card before sending it. The date code is located underneath the base of your unit
(for example, S087R). The additional information will also help us to develop new products that best meet your needs and desires.
Maintenance
Troubleshooting
Cause
1. Nozzle clogged.
2. Suction tube clogged.
3. Material volume setting turned too low (-).
4. Suction tube loose.
5. No pressure build up in container.
6. Air filter clogged.
1. Nozzle loose.
2. Nozzle worn.
3. Nozzle seal worn.
4. Material build-up on air cap and nozzle
1. Viscosity of material too high.
2. Material volume too large.
3. Material volume setting too high (+).
4. Nozzle clogged.
5. Air filter clogged.
6. Too little pressure build-up in container.
1. Material in container running out.
2. Air filter clogged.
1. Applying too much material.
1. Gun too far from spray object.
2. Too much material applied.
1. Moving the spray gun too fast.
7
3. Remove the dirty filter
from the filter cover
and replace with a
new one. The
smooth side of the air
filter must be placed
toward the turbine.
4. Secure the cover back onto the turbine.
Never operate your unit without the air filters. Dirt could
be sucked in and interfere with the function of the unit.
Solution
1. Clean.
2. Clean.
3. Increase volume setting (+).
4. Insert.
5. Tighten container.
6. Change.
1. Tighten.
2. Replace.
3. Replace.
4. Clean.
1. Thin.
2. Decrease volume setting (-).
3. Decrease volume setting (-).
4. Clean.
5. Change.
6. Tighten container.
1. Refill.
2. Change.
1. Adjust material flow or increase
movement of spray gun.
1. Reduce distance.
2. Decrease volume setting (-).
1. Adjust material flow or decrease
movement of spray gun.
English

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

0518899a

Tabla de contenido