Dimensions; Installation Example; Preparing Electrical Connection; Installing The Electric T-Junction - Franke PR3O0002 Instrucciones De Montaje

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

8.

Dimensions

9.

Installation Example

10. Preparing Electrical Connection

Materials required
To be provided by the customer:
• Conduit for system cabels
• Damp-room junction box (≥100 mm × ≥100 mm)
Accessories
Function controller
with Ethernet connection
ECC1 . . . . . . . . . . . . . . . . . . . . . . . . . 2000100368
ECC2 . . . . . . . . . . . . . . . . . . . . . . . . . 2000108123
System cable
blue, 100 m . . . . . . . . . . . . . . . . . . . . 2000104272
blue, 25 m . . . . . . . . . . . . . . . . . . . . . 2000104274
gray, not halogen-free, 100 m . . . . . . 2000100801
gray, not halogen-free, 25 m . . . . . . . 2000100852
Terminating resistor . . . . . . . . . . . . . . . 2000100847
Warning!
• Operate the product only with safety extra low voltage (SELV). Do not earth the
components.
• The power supply (ECC function controller, not included in the scope of delivery,
see accessories) must be set up outside of the wet area, in a separate room.
Failure to observe can mean risk of death or material damage, e. g. from electric
shock or fire.
10.1 Install one damp-room junction box (a) for each fitting.
10.2 Lay the system cable (b) through the conduit, and loop it from fitting to fitting.
Let the system cable hang out of the damp-room junction box approx. 50 cm.
10.3 Connect the electric T-junction (c) (see
10.4 Close up the damp-room junction box with the protective cap.

11. Installing the Electric T-junction

Important!
The components of the electric T-junction must be installed only when they are in a
dead condition.
6
info@hygiene-shop.eu - www.hygiene-shop.eu
Order No.
Chapter
11.).

Publicidad

Tabla de contenido
loading

Tabla de contenido