LaserLiner PrecisionPlane-Laser 3G Pro Manual De Instrucciones página 23

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Checking the vertical line
Position the device about 5 m from a wall. Fix a plumb bob with a line of 2.5 m
length on the wall, making sure that the bob can swing freely. Switch on the
device and align the vertical laser to the plumb line. The precision is within the
specified tolerance if the deviation between the laser line and the plumb line
is not greater than ± 0.75 mm.
Checking the horizontal line
Position the device about 5 m from a wall and
switch on the cross laser. Mark point B on the
wall. Turn the laser cross approx. 2.5 m to the
right and mark point C. Check whether the
horizontal line from point C is level with point B
to within ± 0.75 mm. Repeat the process by turning the laser to the left.
!
Regularly check the calibration before use, after transport and after
extended periods of storage.
Technical data
Self-levelling range
Accuracy
Operating range (depending on room illumination)
Working range with hand receiver depends on how
the technology affects the difference in brightness)
Laser wavelength linelaser
Laser class
Power supply
Operating time
with 3 laser levels
with 2 laser levels
with 1 laser level
Operating temperature
Storage temperature
Dimensions (W x H x D)
Weight (including battery pack)
(Subject to technical changes without notice. 02.17)
PrecisionPlane-Laser 3G Pro
2.5 m
B
± 2°
± 0.15 mm / m
25 m
30 m
515 nm
2 / < 1 mW
Li-Ion rechargeable
battery pack
7.4 V / 5200 mA
Power pack operation
approx. 7 hours
approx. 10 hours
approx. 15 hours
0°C ... +50°C
-10°C ... +70°C
180 x 145 x 125 mm
1.51 kg
C
23
EN

Publicidad

Tabla de contenido
loading