Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
Children as well as adults with physical, mental and/
or sensoric impairments must not use this shower
system without proper supervision. Persons under
the influence of alcohol or drugs are prohibited from
using this shower system.
The hot and cold supplies must be of equal pressu-
res.
Installation Instructions
The fitting must be installed, flushed and tested after the
valid norms!
Thermostatic mixer in conjunction with
combination boilers
•
If fitting a hand shower remove the water limiter from
the shower.
•
If the continuous water heater causes any problems,
or you have different water pressures you must
install a water limiter to the cold supply, (ordered
separately,article number 97510000).
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Rate of flow by 0,3 MPa:
anti-pollution function
English
max. 1 MPa
0,1 – 0,5MPa
1,6MPa
max. 80°C
65°C
20 l/min
Assembly see page 60
Do not use silicone containing acetic acid!
Adjustment / Safety Function
(see page 62)
After the installation, the output temperature
of the thermostat must be checked. A
correction is necessary if the temperature
measured at the output differs from the
temperature set on the thermostat.
Maintenance (see page 63)
•
To guarantee the smooth running of the
thermostat, it is necessary from time to
time to turn the thermostat from total hot
to total cold.
•
The mixer is equipped with non return val-
ves. The non return valves must be chek-
ked regularly according to DIN EN 1717
in accordance with national or regional
regulations (at least once a year).
Dimensions (see page 64)
Spare parts (see page 65)
Operation (see page 66)