Protective Measures - Oase AQUARIUS UNIVERSAL 80 Instrucciones De Uso

Ocultar thumbs Ver también para AQUARIUS UNIVERSAL 80:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Submerged installation (A, B)
Attention! Risk of damage! Ensure that the unit does not take in air or runs dry.
Align the intake of the suction unit (A). Lateral intake: Allows maximum flow, deposits from the bottom are not taken in.
Bottom intake: During operation, intake is possible up to a water level of 0.2 in. (5 mm). Only operate the unit with the
filter housing. Cut the stepped hose adapter to suit the hose diameter and screw onto the return (B1). Place the unit
horizontally with its feet downward (B2).
Dry installation (A, C)
Attention! Risk of damage! Ensure that the unit does not take in air or runs dry. Do not connect the unit to a
water line.
Align the intake of the suction unit upward (A). Operate the unit without filter housing. Cut both stepped hose adapters
to suit the hose diameters, then screw each adapter on the intake and return (C1) Place the unit horizontally with its
feet downward (C2). To prevent air from being taken in, ensure that unit and supply hose are always below the water
level (C2).
Start-up
Attention! The pump must never run dry.
Possible consequence: The pump will be destroyed.
Protective measure: Check the water level at regular intervals. Always place the unit below water level.
Set the flow at the controller (D).
This is how to connect the power supply:
Switching on: Connect power plug to the socket. The unit switches on immediately when the power connection is
established.
Switching off: Disconnect the power plug.
Attention! The installed temperature monitor automatically turns the pump off, if it is overloaded. The pump
automatically switches on again once the motor has cooled down. Risk of accident!
Install the unit so that it is not exposed to direct sun radiation (max. 104 ºF - 40 ºC).
Maintenance and cleaning
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.

Protective measures:

− Prior to reaching into the water, disconnect the power supply to all units used in the water.
− Disconnect the power plug prior to carrying out work on the unit.
Cleaning the unit
Dismantle and clean the unit (E).
If necessary, clean the unit with clear water using a soft brush.
− In the event of stubborn furring (calcium deposits), a common household cleaner free from vinegar and chlorine can
be used. Subsequently, clean the pump thoroughly using clear water.
− Never use aggressive cleaning agents or chemical solutions. These could attack the housing surface or impair the
function.
-
English
-
5

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Aquarius universal 180Aquarius universal 370

Tabla de contenido