Malfunction
Malfunction
The unit does not start
Insufficient fountain height
Unit switches off after a short running period
Storage/Over-wintering
Remove the unit at temperatures below zero degrees centigrade. Thoroughly clean and check the unit for damage.
Store the unit immersed in water or filled with water in a frost-free place. Do not flood the power plug!
Repair
A damaged unit cannot be repaired and must be put out of operation. Dispose of the unit in accordance with the
regulations.

Wear parts

The impeller unit is a wearing part and does not fall under the warranty.
Disposal
Do not dispose of this unit with domestic waste! For disposal purposes, please use the return system provided.
Disable the unit beforehand by cutting off the cables.
6
Cause
No mains voltage
Rotor blocked
Regulator closed too far
Filter housing or rotor soiled, hose blocked
Hose defective
Hose kinked
Rotor worn
Filter clogged
Water temperature too high
Remedy
Check mains voltage
Clean
Set regulator
Clean
Replace
Straighten hose
Replace rotor
Clean
Maximum water temperature: +35 °C (+95 F°)