Secure the metal electrical conduit to the junction box by the UL approved conduit fitting.
House
wiring
UL listed
wire nut
Electrical connections:
o
To connect the "Neutral", joint by a wire nut the white wire (from the conduit) to the white wire from the
junction box.
o
To connect the "Line", joint by a wire nut the black wire (from the conduit) to the black wire from the junction
box.
o
To connect the "Ground", joint by a wire nut the Green/Yellow wire (from the conduit) to the Green/Yellow
wire from the junction box.
Push wires into junction box.
IMPORTANT: Be sure wires are not pinched
Secure junction box cover with original
Metal electrical
conduit
screws.
16