Detecting Faults and problems
PROBLEM: The machine is not working. LED OFF.
Possible cause
The machine is unplugged
No power reaches the plug
The cover is not placed correctly
The handle is not placed correctly
The fuse has blown
Internal damage
PROBLEM: The machine doesn't work the LED is flashing
Possible cause
The waste bucket is separated
from the machine body
Internal damage
PROBLEM: The machine works but the LED is off.
Possible cause
Anomaly inside the
machine
PROBLEM: The machine often gets blocked when juicing.
Possible cause
Not enough voltage
26
Detecting Faults and problems
Corrective measure
Connect the machine to the power supply.
Check the plug.
Make sure that it is placed correctly.
Make sure that it is placed correctly.
Replace (the machine includes a spare one
next to the first one). Figure 1 detail.
Please contact Technical Support.
Corrective measure
Put the waste bucket next to the
machine, in the correct position.
Please contact Technical Support.
Corrective measure
Please contact Technical Support.
Corrective measure
Check that the voltage is the one stated
in the manual.
English