Silo Alarm Weight
Enter here the minimum weight in Kg (Lb) for the main silo. If the silo weight reaches or
drops below this weight the Silo Weight alarm is set off (See Alarm screens on page 24).
If this value is set to 0, the Silo Weight alarm is disabled.
Net Name
This number identifies each RDC on the PC communication network (each RDC must
have a different number). The default value is 1.
Skip Day Counter
In this screen we set up the number of days in the feed/fast cycle and where we are in the
cycle.
Skip Day: Enter here a value ranging from 0-3.
Example: 1= 1 fast day, then feed day
2= 2 fast days, then day feed day
3= 3 fast days, then day feed day
If this value is set to 0, then the system uses the Week Table (see Weekly Table on
page 15).
Counter: Displays where we are in the fast / feed cycle in a numerical format.
When the counter is 0, it is a feed day; otherwise, it is a fast day. The maximum value
shouldn‟t be greater than the Skip Day value.
Example: 0= today is a feed day
1= today is a fast day, tomorrow is a feed day (1 fast day, 1 feed day)
2= today and tomorrow are fast days, the day after tomorrow is a feed
day (2 fast days, 1 feed day)
3= today, tomorrow and the day after tomorrow are fast days, the following day
will be the feed day (3 fast days, 1 feed day)
Use the counter to start the fast/ feed cycle.
Roxell Daybin Controller – RDC
Silo Alarm
Weight:
100 Kg
Net Name
1
Skip Day [0-3]: 2
Counter [0-3]: 2
1