Connect the load cell to the base as shown below. Tighten down the bolts.
Be sure the arrow on the side of the load cell is pointing down
Load Cell connected to base unit
Connect the Joint unit to the load cell. Screw the Joint unit down until it is flush with the
bottom side of the load cell.
Tighten the Lower joint nut to secure the Joint unit to the load cell.

Load cell, joint unit and base

Next place the Upper Channel plate on the Joint unit as seen below.
Upper Channel
Plate
Joint unit
Load cell
Base
After all 4 silo mount leg hardware have been assembled and fasten to the concrete floor,
slowly lower the silo onto the silo mount.
Roxell Daybin Controller – RDC
Joint
unit
Joint unit
nut
Page 28 of 193
Arrow must point down