Operation
Temperature Measurements
WARNINGS:
To avoid electric shock, do not let the temperature
probe contact live circuits.
1. Set the rotary function switch to the Temp °C °F position.
2. Push the °C /°F button to select Celsius or Fahrenheit.
3. Insert the Temperature Probe into the
negative COM and the positive Temp
input jacks, making sure to observe
the correct polarity.
4. Touch the tip of the Temperature Probe
to the part you wish to measure.
Keep the probe touching the part under
test until the reading stabilizes
(about 30 seconds).
5. Read the temperature on the LCD display.
Replacing the Battery
WARNING:
To avoid electric shock, remove test leads from the meter
before removing the battery door.
WARNING:
When replacing the battery or fuses, be sure to secure the back
cover panel and battery compartment door firmly to maintain the waterproof and
dust proof integrity of the meter. Loose or overtightened screws, or an improperly
seated o-ring may compromise the meter's water and dust ingress protection.
1. When the battery drops below the operating voltage, the
appearon the LCD display. The battery
should be replaced immediately.
2. Remove the two Phillips screws
from the battery door located on
the back of the meter.
3. Remove door.
4. Replace battery with a fresh 9V battery.
5. Install battery door and tighten screws.
symbol will
11
Operation
WARNING:
To avoid electric shock, do not operate your meter until
the battery door is in place and fastened securely.
Replacing the Fuses
WARNINGS:
To avoid electric shock, remove test leads from the
meter before removing the fuse cover.
WARNING:
When replacing the battery or fuses, be sure to secure the back
cover panel and battery compartment door firmly to maintain the waterproof and
dust proof integrity of the meter. Loose or overtightened screws, or an improperly
seated o-ring may compromise the meter's water and dust ingress protection.
1. Remove the six Phillips screws that
secure the back cover to the meter.
(Lift the tilt stand to expose the two
bottom screws.)
2. Remove back cover.
3. Remove the old fuse from its holder
by gently pulling it out.
4. Install the new fuse into the holder.
5. Always use an UL rated fuse of the
proper size and value
(0.5A /1000V (6.3 x 32mm) fast blow
for the 400mA range,
(10A/1000V (10 x 38mm) fast blow
for the 10A range.
6. Install back cover and tighten screws.
WARNINGS:
To avoid electric
shock, do not operate your meter until the
battery and fuse cover are in place and
fastened securely.
A
A
9V BATTERY
A
A
A = Back Cover Screws
B = Battery Screws
10A FUSE
0.5A FUSE
12
B
B