Disconnect PHONES
• When the headphones are connected,
measuring the output signal of the amplifier
(LAPC) will not start.
• Disconnect the headphones.
• If you connect headphones during amplifier
signal measurement or amplifier output
correction, it will be cancelled. ( 22)
"F
" (" " stands for a number.)
• An abnormality has occurred. (If this unit
detects an abnormality, the protection circuit
is activated, and the power may be turned off
automatically.)
- Is the volume extremely high? Or is this unit
placed in an extremely hot place?
Wait a few seconds and then turn the unit
on again. (The protection circuit will be
deactivated.)
Load Fail
• The firmware cannot be found on the USB flash
memory.
• Download the latest firmware on the USB flash
memory and try again. ( 23)
Measurement Fail
• The measurement or processing of "Cartridge
Optimiser" fails. Make the following checks.
"High Level":
The output signal is so noisy or the output
signal level of turntable is too high. Remove the
dust from the record. Confirm the setting of
"Gain" and adjust the input level of this unit
( 16).
Check if "MM/MC" setting of this unit matches
the cartridge type of the turntable or not
( 16).
"Low Level":
The record is not played back, or the output
signal level of turntable is too low. Confirm the
turntable is connected correctly and the record
is played back properly ( 16).
Confirm the setting of "Gain" and adjust the
input level of this unit ( 16).
Check if "MM/MC" setting of this unit matches
the cartridge type of the turntable or not
( 16).
"Low Quality":
The output signal of turntable is so noisy.
Remove the dust from the record. Or play
another track. If the problem still persists,
consult your dealer.
"Speed Mismatch":
Rotation per minute (RPM) is incorrect. Adjust
the rotation of turntable and play back in
correct RPM.
"System Error":
It may be system error. Consult your dealer.
No Device
• USB flash memory with new firmware is not
connected.
Connect the USB flash memory with new
firmware. ( 23)
Not Measured
• Measuring the output signal for the output
correction function (LAPC) has not been done
yet.
• Measure the output signal. ( 22)
Not Valid
• The function you have tried to use is not
available with the current settings. Check the
steps and settings.
• The current input source is different from the
one in "Cartridge Optimiser" setting. Switch the
input source correctly. ( 16)
• [MUTE] is not valid while the measurement of
"Cartridge Optimiser". Adjust the volume.
PHONES Connected
• The headphones are connected.
• Sound is not output from headphones jack and
speaker output terminals when the headphones
are connected and "MAIN IN" is selected as
input source of this unit. ( 18)
"Remote
" (" " stands for a number.)
• The remote control and this unit are using
different modes.
Change the mode on the remote control. ( 11)
Unlocked
• "COAX1", "COAX2", "OPT1", "OPT2", "PC1" or
"PC2" is selected, but no device is connected.
Check the connection with the device.
( 13, 14)
• The sampling frequency components, etc. of
the audio signals are not input correctly.
- About supported format, refer to "Format
support". ( 28)
USB Over Current
USB device is drawing too much power.
• Disconnect the USB device and connect it
again. ( 23)
• Turn the unit to standby and on again.
VOLUME
OK (" " stands for a number.)
• When the input source is switched from "MAIN
IN", the volume level after switching the input
source is displayed.
• Confirm and adjust the volume before pressing
[OK].
27
Troubleshooting
(27)