B
fig. 1
A
fig. 3
D
fig. 5
fig. 6
G
fig. 8
fig. 9
L
M
INSTALLATION
fig. 2
D
C
C
fig. 4
E
F
fig. 7
H
I
fig. 10
L
M
1) VERSION WITH GLASS SIDES AND TOP
The stove is delivered with the sides and top removed and
protected for the transportation phase.
To remove the protection, proceed as follows:
- Remove the glass top (A - fig. 1) by cutting the fastener (B -
fig. 1) and remove the four spacers and the central bracket (C/D
- fig. 2).
- Open the door and remove the galvanised panel (D - fig. 3)
- Slacken the wing nuts at the lower and upper ends on the
inside of the glass sides (E/F -fig. 4/5).
- Close the door and remove the plating profiles on the back
(G - fig. 6).
- Take the glass sides off (H - fig. 7) and remove the protection
- Remove the rubber pads fixed under the fixing brackets (up-
per and lower) for the glass sides (I - fig. 8)
- Remove everything and the repeat the steps listed in reverse
order
- Before repositioning the glass top, fit the 5 rubbers and 10
washers supplied into their housings in the cast iron top (L/M -
fig. 9/10).
2) VERSION WITH STEEL SIDES AND GLASS
TOP
The stove is delivered with the sides and top fitted, complete
with protection for the glass top for the transportation phase.
To remove the protection from the top, proceed as indicated
above.