Fault Correction; Replacement Parts - Franke AQRE431 Instrucciones De Montaje Y Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 17

15. Fault correction

Fault
Water does not flow
at all
Water flows
continuously
Water flow too weak
Water flow too large

16. Replacement parts

Designation
1 Cover plate . . . . . . . . . . . . . . . . . . . . . 85-100-20.663
2 Control unit . . . . . . . . . . . . . . . . . . . . 85-100-07.978
3 Solenoid valve cartridge 6 V – . . . . . 85-032-01.364
4 Mounting frame . . . . . . . . . . . . . . . . . 85-100-20.329
5 Battery compartment with battery . . 85-100-07.973
5a Lithium battery 6 V CR P2 . . . . . . . . . 85-032-02.830
6 Flushing plugs/assembly key . . . . . . 85-017-02.077
7 Valve seat with O-ring . . . . . . . . . . . . 82-500-01.017
8 Maintenance kit comprising:
O-ring
Safety ring. . . . . . . . . . . . . . . . . . . 82-500-03.019
Replacement parts set for DN 20 consisting of:
Rubber parts. . . . . . . . . . . . . . . . . 82-500-01.031
Cause
– Water supply interrupted
– Flow volume regulator closed
– Battery dead (LED flashes)
– Solenoid valve faulty
– Solenoid valve dirty
– Solenoid valve faulty
– Flow volume regulator not fully
opened
– Supply pressure too low
– Flushing flow adjustment incorrect
– Flush volume adjustment incorrect
– Flush volume adjustment incorrect
– Flushing flow adjustment incorrect
– Flow volume regulator opened too far
Order No.
Accessories
9 AQUA remote control . . . . . . . . . . . . 5179 0000
Remedy
➯ Restore
➯ Open it
➯ Replace it
➯ Replace it
➯ Clean it
➯ Replace it
➯ Open it
➯ Check it
➯ Adjust it
➯ Adjust it
➯ Adjust it
➯ Adjust it
➯ Close it
Order No.
9

Publicidad

Tabla de contenido
loading

Tabla de contenido