6.1 How it works
You use the RKMultiControl controller to move Rose+Krieger drives.
Depending on the design, up to two drives can be connected to the controller. You use a hand
switch to operate the controller. The battery provides the option to operate the controller inde-
pendently of the mains.
6.2 Technical specifications
Type/Model
Dimensions W × H × L
Weight
Supply voltage (primary)
(depending on design)
Type of protection
max. current drain (primary)
max. output current
Duty cycle
Supply capacity rechargeable
battery/type
Rated capacity (20 hours
assessed)
max. discharge current
max. charging time
Charging cycles at 30% discharge
Battery lead length
Protection class
Ambient temperature
Relative humidity
Ambient air pressure
RKMultiControl duo accu
1.2 Ah
110 × 98 × 335
1.5 kg battery
3.5 kg controller
230V AC (±10%) 50/60 Hz
115V AC (± 10%) 50/60 Hz
2A (230V AC 50/60 Hz)
4A (115V AC 50/60 Hz)
6A per drive/total 12A
20 % duty cycle/10 min
1.2Ah
5A
150 mm
from 700 hPa to 1060 hPa
6. Product information
RKMultiControl duo accu
160 × 90 × 250 battery
110 × 62 × 335 controller
5.6 kg battery
3.5 kg controller
IP 30
24 V/Lead-gel
approx. 14 hours
approx. 1000
450 mm
II
+5°C to +40°C
30% to 75%
7 Ah
7Ah
10A