RK Rose+Krieger RKMultiControl duo accu Instrucciones De Montaje página 51

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

6-key hand switch and 8-key wireless hand switch
Ensure that all drives and controllers are interconnected and that the mains plug is connected.
Press the F key three times (see section 7.12.1). If the access code has still not been entered,
"PArA" appears in the display.
Enter the access code. The access code is: 13121.
6-key hand switch: Press the keys in this sequence: I - III - I - II - I
8-key remote hand switch: Press the keys in this sequence: 1-3-1-2-1.
If the access code has been entered correctly, "P---" appears in the display.
Use the hand switch keys to enter the 3-digit code (211) to start the initialisation run.
Note: "[In d]" appears in the display.
Press the DOWN key
end stop.
Note: When the lower end stop is reached, "[In U]" appears in the display.
Press the UP
key and keep it pressed until all drives have moved to the upper end stop.
Should it be impossible to reach the top end stop, the initialisation run can be ended in any po-
sition by keeping the DOWN key
the drives.
The initialisation run is complete. The controller is now ready for operation. The operation of the
2-key or 6-key hand switch is described in sections 7.11. and 7.12.
We recommend that you perform the initialisation run with a hand switch with display. You can
read in the display when the top and bottom end stops are reached.
An initialisation run must be fully completed because the drives will not move otherwise.
again and keep it pressed until all drives have moved to the lower
pressed for 5 seconds. The position is the new end stop for
7. Working life
51

Publicidad

Tabla de contenido
loading

Tabla de contenido