7.9 Settings table (configuration)
All the settings which you can perform on drives are described in the following table. Read in sec-
tion 7.8 for instructions on how to perform the settings.
Configurations marked with this symbol can sometimes pose a danger to persons
or damage the drives or other objects if the setting is incorrect.
Code
Determine the addresses for the connected controllers:
0
= Off (if the controller is used independently)
113
1
= Master (address of the first controller)
2-8
= Slave (addresses of the remaining connected controllers)
Default height for the display: set which value is to be shown in the hand switch display
with the drive retracted.
133
Example: If the column has an installation height of 610 mm, then the
parameter could be set to 610.
Start initialisation: Start initialisation run without pulling out the controller mains plug
211
beforehand.
Column travel: Change the height indication in the display.
If you set the setting
213
Example: If the column has an installation height of 460 mm, then the
parameter could be set to 460.
Determine the duty cycle: determines the time (in percent/10 minutes), during which the
drives can be moved without interruption.
If you set the duty cycle e.g. to 20%, the drives can be moved for a maximum of 2 minutes
without interruption. After this, you cannot move the drives until 8 minutes have passed.
232
Note: In the factory setup, the duty cycle is 100 %, i.e. the drives can be moved
for as long as you like without interruption! Despite this 100%, always
observe the duty cycle of 15% for the drives and controllers!
Activation of the load resistor (only with
Switching the load resistor in or out with interconnected controllers.
233
0 = off (load resistor deactivated)
1 = on (load resistor activated)
Changing the position of the decimal point of the height indication in the display:
.xxxx
xxxx.
311
xxx.x
xx.xx
Description
0
, the height in the display is indicated in % ("
RKMultiControl
7. Working life
xxxP."
)
quadro):