Checking the vertical line:
Position the device about 5 m from a wall. Fix a plumb bob with a line of 2.5 m length on the wall, making
sure that the bob can swing freely. Switch on the device and align the vertical laser to the plumb line.
The precision is within the specified tolerance if the deviation between the laser line and the plumb line
is not greater than ± 1 mm.
Checking the horizontal line:
Position the device about 5 m from a wall and switch on the cross laser. Mark
point B on the wall. Turn the laser cross approx. 2.5 m to the right and mark
point C. Check whether the horizontal line from point C is level with point B
to within ± 1 mm. Repeat the process by turning the laser to the left.
!
Regularly check the adjustment before use, after transport and after extended periods of storage.
Information on maintenance and care
Clean all components with a damp cloth and do not use cleaning agents, scouring agents and solvents.
Remove the battery(ies) before storing for longer periods. Store the device in a clean and dry place.
Technical data
(Subject to technical alterations 18W10)
Self-levelling range
Precision
Levelling
Operating range (depending on room illumination) 20 m
Laser wavelength
Laser class
Power supply
Operating time
Operating conditions
Storage conditions
Weight (incl. batteries / without magnetic base)
Dimensions (W x H x D)
EU directives and disposal
This device complies with all necessary standards for the free movement
of goods within the EU.
This product is an electric device and must be collected separately for disposal
according to the European Directive on waste electrical and electronic equipment.
Further safety and supplementary notices at:
http://laserliner.com/info?an=crodotlas5
CrossDot-Laser 5P
± 4°
± 0.2 mm / m
automatic
635 nm
2 / < 1 mW
4 x 1.5 V alkaline batteries (type AA)
approx. 16 hours
0...50°C, max. humidity 80% rH,
no condensation, max. working altitude
4000 m above sea level
-10...60°C, max. humidity 80% rH
535 g
119 x 108 x 77 mm (CDL 5P)
2,5 m
B
C