3.1
Technical data
Table 3-1: Technical data
Exhaust Hose Reel
Weights, short reel,
without hose
Weights, short reel,
with hose and nozzle
Weights, wide reel,
without hose
Weights, wide reel,
with hose and nozzle
Recommended mounting height
Duct connection
Recommended airflows,
cars, 75–100 mm (3"–4") hose
Recommended airflows,
trucks, 125–150 mm (5"–6") hose
Operating temperature
Hose temperature resistance,
Hose NR-CP or NTP
Hose temperature resistance,
Hose NFC-3
Noise level, Measured according to ISO 11201.
Material recycling, Reels without hose
4
Installation
4.1
Installing Serial 865
See Figure 2. Maximum mounting height for the reel is 6 m.
1.
Make sure that the surface, on which to mount the reel, is level. Drill 4
holes, using the hole template which comes in the package.
2.
Fit the mounting brackets in such a way that will make the reel hanging
horizontally. Ensure that suitable fixing bolts are used considering the
ceiling or wall construction material. The bolts must each stand a tractive
force of minimum 6500 N.
3.
Use approved lifting equipment to lift the reel. Fasten the reel in the
brackets.
12
144233(02)
23 kg (51 lbs)
30–40 kg (66–82 lbs)
31 kg (68 lbs)
40–50 kg (82–110 lbs)
Maximum 6 m (20 ft)
Ø 160 mm (6.3 in)
400–600 m
/h (235–350 cfm)
3
800–1200 m
/h (470–700 cfm)
3
–10 °C to +50 °C (15 °F to 120 °F)
150 °C (300 °F) continuously
300 °C (570 °F) continuously
< 70 dB(A)
100 weight-%