EN
E6
E7
E8
E9
EA
EH
TC = TOUCH CONTROL
UI = USER INTERFACE
NTC = TEMPERATURE SENSOR
The power supply voltage
The power supply
does not fall within the
voltage does not fall
range (see technical data
within the range (voltage
for details).
and/or frequency). The
cooking area cannot be
Internal error in generator
activated
circuits.
TC internal error. The
cooking areas are
-
deactivated.
The suction hood is blocked.
Suction hood
Faulty fan or electronic
malfunction.
module.
Cooking area
The temperature sensor
temperature sensor
circuit is open or there is a
error. The corresponding
short-circuit.
cooking area is Off.
TC internal error. The
-
cooking areas are Off.
Temperature sensor
No change in temperature
blocked. The
(min. 10 K / 5 min.) after
corresponding cooking
activation of the cooking
area is Off.
area.
FMA 839 HI
Check the mains voltage.
Replace the module.
Replace the module.
Clean and remove any blocks.
Replace the module.
Replace the inductor.
Replace the generator.
Replace the inductor.
– 26 –