AIR DUCTING FEATURES
The stove has 2 independent outlets for air ducting.
Air ducting 1 - 2 are enabled by factory default.
Features:
diameter of air ducting outlet: 2x80 mm
maximum recommended air ducting length 8 m
temperature controlled air ducting
Speed regulation can be set in 3 modes: OFF, AUTO, COMFORT
independent air ducting with option for enabling/disabling (ON OFF)
FACTORY DEFAULT OPERATION IN AIR DUCTING MODE
Air ducting 1 and 2 are always in request by factory default (jumpers on 1 and 2 present), and follow the stove settings.
- No settings necessary.
OPERATION IN AIR DUCTING WITH THERMOSTAT OR PROBE OPTIONAL
The stove is tted with two independent motors for air ducting. The connection of an external thermostat or temperature probe (NTC 10K)
in inputs 1 and 2, located in the rear part of the stove, makes it possible to control the air ducting motor independently of the stove.
Su ce it to connect the thermostat/temperature probe and set the desired temperature.
For information on air ducting settings see chapter:" MENU AIR DUCTING"
WITH AMBIENT THERMOSTAT OPTIONAL
Remove the jumper on 1 and connect the ambient thermostat in the room that needs to be temperature-controlled through air ducting 1.
3 control modes:
OPERATION IN AIR DUCTING WITH AMBIENT THERMOSTAT OPTIONAL
SET con gured to OFF
(the temperature setting is not visible)
SET con gured to AUTO
(the temperature setting is not visible)
SET con gured to COMFORT
(the temperature setting is not visible)
WITH PROBE NTC 10K
Remove the jumper on 1 and connect the NTC probe in the room that needs to be temperature-controlled through air ducting 1.
3 control modes:
The air ducting motor will remain o unless the fumes temperature exceeds the
normal operating temperatures
Once the speci c activation threshold has been reached and exceeded, at temperature
to be satis ed (CLOSED CONTACT) the air ducting motor will follow the stove settings.
When the temperature set on the thermostat is reached (OPEN CONTACT), the air
ducting motor will switch OFF and switch on again when there is a new request.
Once the speci c activation threshold has been reached and exceeded, at temperature
to be satis ed (CLOSED CONTACT) the air ducting motor will follow the stove settings
but at a lower speed than in SET AUTO for increased acoustic/ambient comfort.
When the temperature set on the thermostat is reached (OPEN CONTACT), the
ducting motor will switch o and switch on again when there is a new request.
SAME OPERATING SETTINGS FOR AIR DUCTING 2 MOTOR
ENGLISH