4. ELECTRICAL INSTALLATION
CAUTION All work on the pump can only be carried out after disconnecting
the electrical supply.
The electrical network must have the same rating as on the nameplate.
CAUTION the pump must be connected to the electrical installation by means of a
plug with a socket that has an earthing connection (the yellow and green wire is connected
to earth).
The Producer and Guarantor are exempt from any liability for any damage caused to people
or things resulting from the lack of proper grounding or protection.
CAUTION
equipped with a residual current device with a rated inrush current of no more than 30 mA.
The manufacturer and guarantor are exempt from any liability for damage caused to people
or things resulting from the pump's power supply, bypassing the appropriate switch.
CAUTION The pump should be connected to the mains supply equipped with
over current protection, eg M611, which will protect the pump motor against possible
overloading. The switch should be set to the maximum winding current indicated on the
nameplate. If the user does not use such protection in the event of motor damage resulting
from overloading, the user will have to bear the repair costs.
CAUTION Mechanical damage is not subject to warranty repairs free of charge. In
the event of damage to the cable insulation, do not use the pump, immediately contact the
guarantor to replace the cable.
CAUTION The pump must not be used when the voltage drops below 210V, because of
possible overloading and destruction of the pump motor.
5. START-UP AND OPERATION
CAUTION Before the first start-up or after a long period of non-use of the pump, make sure
that both the pump and the suction installation are flooded with water.
CAUTION the pump is not equipped with dry-running protection.
CAUTION Before first starting the pump or the hydrophore, make sure that all taps
or valves are unscrewed in order to allow the air to get out of the system. Commissioning
should take place after connecting the power plug to the mains. If the pump is not working
(the motor is buzzing but the fan is not spinning), make sure that the rotor or hydraulics are
not blocked, turn off the pump and insert the screwdriver through the fan casing and try to
move the fan. If the fan turns freely and the pump still does not work, please contact your
dealer.
CAUTION If the pump is running and water does not come out of taps, there is a suspicion
that the installation is leaking, to make sure you put a piece of hose on the tap or place a tap
outlet in a bowl of water and check for air bubbles. If so, it means a leak in the suction unit.
Pump operation in this case, i.e. without water flow, can lead to its destruction. Repairs of
this type will take place in paid form. If the pump does not start normally after a few
minutes, check that the suction system is primed and that there are no leaks in the system
through which the pump will suck in air instead of sucking water. After the air has been
Electrical installation supplying the pump should absolutely be