CAUTION Inspection and filling of the air pressure in the tank are responsibility of
the user
7. STORAGE
CAUTION, PLEASE NOTE THAT IF THE PUMP WILL NOT BE USED
FOR A LONGER PERIOD THAN ONE DAY SHOULD BE DEEMBED FROM THE
ELECTRICAL SUPPLY. Otherwise, if there is a leak in the system, the pump can start
automatically, which can lead to flooding of the house or flooding the pump. All costs
associated with the repair of damage related to such events will have to be borne by the
user.
CAUTION IF THE PUMP / HYDROFOR WILL NOT BE USED FOR A
LONGER PERIOD, WATER COMPLETELY COMPLY WITH THIS WATER.
CAUTION If the hydrophore / pump is to be used in winter, it must be protected against
freezing. All repairs resulting from damage to the pump by the action of frost will take place
in paid mode. If, however, the hydrophore / pump will not be used during the period when
the temperatures may drop below 0 ° C, the water should be drained from it. The easiest
way is to unscrew the drain screw and incline the pump, which will facilitate emptying the
pump's hydraulic chamber. In the case of a hydrophore, unscrew the anti-vibration hose
from the tank's flask and tilt it to empty the water. It should be remembered that remaining
water in the tank or pump may cause damage, which is not covered by the warranty.
CAUTION All work on the pump may only be carried out after disconnecting
the electrical supply.
8. POSSIBLE CONSUMER PROBLEMS AND THEIR SOLUTION:
symptoms:
Pump and pump
motor do not work
Possible cause:
No power supply
he switch-on pressure is set too low
Solution:
Check that the electric plug of the
pump is properly inserted into the
socket. Check the "plugs" at
home and all kinds of installation
fuses that can turn off the power
supply from the network
Check if electricity is provided
near your home - electricity can
be disconnected by a power
company in a larger area
Set the higher switching pressure
using the screw in the pressure
switch