The pump does not
pump water even
though the pump
motor is on
The pump switches
on and off every now
and then

9. DISPOSAL OF THE DEVICE

The above symbol indicates that the disposal of used equipment together with
other waste is prohibited. Detailed information on this subject can be found in
municipal waste treatment plants, city offices, municipal offices. The used
device is obliged to be disposed of as waste only in separate collection of
waste organized by the Network of Municipal Electric and Electronic Waste
Points. The consumer is entitled to a free return of waste electrical and electronic equipment
(WEEE) in the network of the equipment distributor, warehouse or store where he bought the
goods, provided that the returned device is of the proper type and fulfills the same function as
the newly purchased device.
The pump is blocked
(Pump shaft)
The water table is too low
Leaks on the installation
Lock of the check valve
The pump is not completely
immersed in water
The temperature of the water being
pumped is too high.
Ambient temperature too high
Tank pressure too low or too high
Leaking of the discharge installation
Leaking check valve
Disconnect the pump from the
power supply. Insert a screwdriver
through the fan casing and try to
move the fan.
Place the suction hose in the
water, if after joining the sections
the water column is up to 8 m
Seal the suction installation
Check that the non-return valve
has not been blocked
Check the water level in the
pump sump.
Check that the water temperature
is not too high for the type of
pump.
Lower the temperature, for
example, by ventilating the room
Pump or drain the air to / from the
tank using the valve
Seal the installation
Replace the check valve