Replacing The Motor - Titan CAPSPRAY HVLP Manual Del Propietário

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Replacing the Motor

1. Perform CLEANUP procedure.
2. Adjust pressure to PRIME position.
3. Remove siphon and return tubes.
4. Remove material hose.
5. Remove pump from turbine, ensuring power is removed.
6. Tip pump on its side to drain excess solvent. The unit
should be tipped on the side that contains the fittings for
the siphon/return tubes.
7. Remove the return tube fitting.
8. Using a thin blade, slit top label down the center to allow
the case halves to separate.
9. Remove heel cover.
Heel
cover
10. Remove the ten (10) case screws.
NOTE: Do not forget the
single screw on the
other side of the
pump or the the small
#4 screw near the
electrical connection.
11. Gently pull apart case halves away from pump housing
assembly.
12. Remove the two (2) connectors from motor terminals.
13. Remove the four (4) gear case screws from pump
housing. Remove the gear case.
Motor
Gear case
screw
© Titan Tool. All rights reserved.
Return
tube
fitting
Screw
Screw
Gear case
Eccentric
Gear
Case
screw
11
14. Remove two (2) motor screws from gear case. Remove
the motor.
Gear
case
Motor
screw
15. Inspect the gears and eccentric. Apply a film of piston
lube.
IMPORTaNT: Lubricate as shown below. apply grease only
where indicated. additional grease can cause excessive
drag on the motor and cause overheating.
16. Assemble in reverse order using the following torques:
a. Motor Screws (2) = 4-6 in-lbs
b. Gear Case (4) = 12-15 in-lbs
c. #6 Case screws (9) = 5-6 in-lbs
d. #4 Case screw (1) = 1-2 in-lbs
e. Heel cover screws (3) = 6-8 in-lbs
f. Return tube fitting (1) = 15-20 in-lbs
Piston Lube™
Motor
Grease this gear
face only
Piston Lube™
English

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

0524038

Tabla de contenido