Specifications
Max working flow rate .... 20 fl oz./min at 35 PSI
Max flow rate flushing
(Free flow) ..................... 40 fl oz./min
Maximum working
pressure......................... 35 PSI (2.4 MPa)
Power ............................ PMDC brushed motor, 120 VAC, 60 Hz,
0.40 A
Weight ........................... 3.3 lbs (1.5 kg)
Hose length ................... 30 ft (9.1 m)
Introduction
The HVLP Transfer Pump is designed for use with CAPspray
spray systems. The Transfer Pump adds tremendous versatility
to an already complete system. This system improves user
productivity during larger spraying jobs by siphoning material
directly from a material container instead of spraying from a
1-quart cup.
Components of the HVLP Transfer Pump include a Transfer
Pump, material hose, siphon tube and a return tube.
This unit is to be used in conjunction with Titan CAPSpray
series turbines, sold separately (models CS75, CS95, CS105 or
CS115).
Speed
setting
knob
Connector
Fuse
Siphon tube
fitting
Return tube
(smaller diameter)
Siphon tube
(larger diameter)
*Material hose not shown
With this HVLP spray system, you can achieve the highest
quality professional finish possible with little preparation or setup
time. Please review all the information contained in this manual
before operating the system.
Bypass Design
The pump is a positive displacement pump and will run
continuously. It differs from a typical airless piston pump in that
during operation, material will continuously circulate into the
pump and out the return tube unless the gun is triggered.
© Titan Tool. All rights reserved.
ON/OFF switch
Pressure
setting knob
Outlet
valve
Return tube
fitting
Inlet valve
tool
Siphon
filter
3
Transfer Pump controls
Speed settings
The speed setting is used to adjust the volume of material
available to the spray gun. It is best to use the lowest speed
possible in order to maximize seal life. For most applications,
LOW speed will perform sufficiently while putting the least
amount of wear of the seals.
MEDIUM
LOW
• LOW - up to 14 fluid ounces per minute
• MED - up to 17 fluid ounces per minute
• hIGh - up to 20 fluid ounces per minute
• FLuSh - 40 ounces per minute (to be used only during
cleanup)
Pressure settings
The pressure setting is used to determine the amount of force
used to deliver the material. The pressure settings range from
PRIME (no pressure) to 6 (max pressure).
The pressure is determined by the figure shown at the 6:00
position (when looking directly at the front of the pump) on the
pressure setting knob.
6:00
HIGH
FLUSH
PRESSURE
PRIME
English