Fpmcpu, Front-Plate Cpu Module; Ifm24160, Power-Supply Module - INIM Electronics PREVIDIA216 Manual De Instalación

Ocultar thumbs Ver también para PREVIDIA216:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 45
Installation manual
3.2

FPMCPU, front-plate CPU module

The FPMCPU module is the main unit of the control panel and contains the main CPU with all the system configuration
data.
Each module in the Previdia Max system has its own independent CPU. Each FPMCPU unit contains two CPUs: a main
CPU and a emergency backup CPU. The backup CPU will take over in the event of fault on the main CPU.
The emergency backup CPU ensures the efficiency of the basic functions of the system (alarm signal reception from
points and activation of outputs). However, it does not ensure all the configured activation logic. For total redundancy of
all the configured functions, it is necessary to add and configure a second FPMCPU unit to the control panel.
[A]
Touchscreen display
[B]
[C]
LED and function button
[D]
LED and multiple-alarm button
[E]
Access-key slot
[F]
[G]
Ground connection wire
[H]
Mounting screw locations
[I]
CR2032 battery (included, for internal clock)
[J]
MicroSD card holder
[K]
Button to reset default settings (factory settings)
[L]
FPM-CPU module - technical specifications
Power supply voltage
Operating temperature
stand-by
Consumption @
maximum
27.6V
mains fault
Maximum voltage on RS485-REPEATER
Maximum voltage on RS485-BMS
3.3

IFM24160, power-supply module

The IFM24160 internal module supplies and distributes power through the CAN drive connection bar and through the
two outputs, OUT 1 and OUT 2.
In installations where several control panels are connected in a network, it is necessary to use an IFM24160 power-supply
module for each control panel.
In installations where the control panel comprises more than one cabinet, you can install a power supply in each cabinet.
The total voltage available equals the sum of the voltages of each power supply added together minus 1A for correct
cable balance.
Description of the parts
Figure 4 - FPMCPU
Status LED
Speaker
Reset button
19-30V
supplied by IFM24160 module
from -5°C to +40°C
130mA
140mA
110mA
1A @ 27.6V
1A @ 27.6V
[M]
[N]
CAN bar connector
[O]
Connector for other front-plate module
[P]
RS485 terminal board for repeaters
[Q]
EOL jumper connectors
[R]
RS485 MODBUS terminal board
[S]
MODBUS EOL jumper connectors
[T]
[U]
[V]
Serial connector
[W]
programming jumper connectors
Ethernet port
For future use
USB mini port
25

Publicidad

Tabla de contenido
loading

Tabla de contenido