Electrical Data; Table 4: Electrical Data - Astralpool ASTRAL CDP Serie Manual Técnico. Puesta En Marcha Y Funcionamiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

The electrical installation must be carried out by a qualified professional (an electrician, for
example) according to the applicable laws and regulations of the target country.
The dehumidifier circuit must be linked to a safety earth circuit levelled to the terminal block.
The cables must be correctly installed so that they do not cause interferences (items in the
lead boards).
The unit may be connected to an earthed 230/2/50Hz general-purpose power supply.
Next table shows some indicative sections, which must be verified and adapted according to
the installation needs and conditions.
All wiring should comply with local and national electric codes and should not be prone to
overheating and subsequent voltage failures. As a guide, you can use the general power
supply table for lengths of less than 25 metres.
The acceptable tolerance to voltage fluctuation is +/- 10% during operation.

4.2.1 Electrical data

Voltage. (V)
2
Section (mm
)
Nº of wires.
Compressor. (A.)
Fan. (A.)
TOTAL.
Voltage. (V)
2
Section (mm
)
Nº of wires.
Compressor. (A.)
Fan. (A.)
Electric Battery. (A.)
TOTAL.
Voltage. (V)
2
Section (mm
)
Nº of wires.
Compressor. (A.)
Fan. (A.)
TOTAL.
© ASTRALPOOL 2008. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
6,01
7,04
1,1
1,1
7,1
8,1
Amp.
220
4
2P+Ground
6,01
7,04
1,1
1,1
18,2
18,2
25,1 Amp.
26,1 Amp.
6,01
7,04
1,1
1,1
7,1
8,1
Amp.

Table 4: Electrical data.

220
4
2P+Ground
9,1
1,1
10,1
Amp.
Amp.
2P+ Ground
9,10
1,1
22,7
33,2 Amp.
220
4
2P+Ground
9,1
1,1
10,1
Amp.
Amp.
ENGLISH
10,4
1,1
11,5
Amp.
220
6
10,40
1,1
22,7
34,5 Amp.
10,4
1,1
11,5
Amp.
Page 46 of 69

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Astral cdp-2Astral cdp-3Astral cdp-4Astral cdp-5

Tabla de contenido