Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may not be used as a holding handle. A
separate handle must be installed.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• Connection with flexible hose code nr. 58192000.
(see page 35) Fig. A
Installation to DIN 1988
(see page 35) Fig. B
Installation to EN 1717
(see page 35) Fig. C
When assembling the iBox universal with integrated
safety combination (HD) pay attention that the middle
of the mixer is min. 280 mm above the upper edge of
the bath tub.
Use of the flush plug
(see page 35) Fig. D
• Testfilling of the bath tub.
• Flushing of the pipes.
• Pressure test of the pipes between mixer and flush
plug
• The residual water jet during pressure test is taken
into account. It shall remind you of closing the mixer
after the pressure test and avoid cross flow at the
mixer.
4
English
Assembly (see page 32)
Technical Data
Sequence power:
overflow capacity:
Symbol description
Do not use silicone containing acetic acid!
Dimensions (see page 38)
Flow diagram (see page 37)
Spare parts (see page 40)
XXX = Colors
000 = Chrome Plated
340 = Brushed Black Chrome
830 = Polished Nickel
950 = Brushed Brass
Special accessories (order as an extra)
• connection hose #58192000
(see page 40)
Test certificate (see page 35)
The sound level test symbol P-IX 19141/I is only valid if
connection hose 58192000 is used.
53 l/min
45 l/min