Descargar Imprimir esta página

Teuco Hydrospa 620 Manual Del Usuario página 34

Ocultar thumbs Ver también para Hydrospa 620:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 106
EN
8. Powering up the system
Set the filter pump switch to "STOP".
Power up the control panel by setting the main
switch to "ON".
The filler solenoid valve will cut in automatically to
bring the water up to operating level in the overflow
tank .
Set the filter selector valve to "3" (RINSE).
Set the pump switch to "MAN" (manual).
Water will now flow from the overflow tank into the
filter, washing the sand, and from the filter directly
to the drain.
After 30-40 seconds operation, shut off the rinse
flow by setting the pump switch to "STOP".
9.
Shift the selector lever to position "1" (FILTER) .
Set the pump switch to "MAN" (manual).
Water will begin flowing from the pool through the
filter.
620
34

Hide quick links:

Publicidad

loading