This equipment is not intended for use by persons (including children) with limited physi-
cal, sensory or mental abilities or for persons with no experience or knowledge unless they
are supervised by a person responsible for safety or unless they have received from such a per-
son instructions on how to use the equipment. Children should be supervised to ensure that they
do not play with the equipment.
Notice: These devices produce magnetic fields which might cause electronic and
20 cm
mechanical disturbances or damages. This also refers to pacemakers. Please
consult the manuals of medical equipment for the required safety margins.
Attention: Maintenance work presents the risk of crushing the fingers due to high magne-
tic forces.
For your own safety, we recommend to form a drip loop with the connec-
tion cable to prevent any water running along the cable from intruding
into the socket. When using a multiple socket or an external power supply unit,
position them atop the filter's power connection.
Since a wide variety of varnishes and polishes are used when processing
timer, the appliance feet can leave visible traces on furniture or parquet
floors as a result of chemical reactions. Therefore the device should not be pla-
ced on unprotected wooden surfaces.
To achieve optimal operational safety there must be a maximum of 100 cm
between the surface of the water and the bottom of the filter. Attention:
Filter must always be operated in an upright position only.
Take the necessary precautions when handling components that can dis-
charge static electricity.
Do not clean the unit – or parts of it – in the dishwater. Not dishwater resistant!
Do not dispose of this product as normal household waste. Take it to your local refuse col-
lection side.
The product is qualified in accordance with the respective
national regulations and guidelines and meets EC standards.
EHEIM External Filter aquacompact 40 and aquacompact 60
Installation
See side flap:
1. Sealing plug 2. Nozzle tube 3. Elbow 4. Sleeve 5. Nozzle 6. Pump impeller 7. Pump cham-
ber cover 8. Screw for pump chamber cover 9. Extension piece 10. Filter sponge 11. Filter bas-
ket 12. Pump casing 13. Hose connection piece (pump) 14. Hose clamp 15. Silicon hose
16. Fastening clip 17. Filter container head 18. O-ring 19. Fibrous filter material 20. Filter ma-
terial EHEIM SUBSTRATpro 21. Filter mat 22. Filter container 23. Elastic pads 24. Partition
25. Power regulator.
First stick the three elastic pads (23) onto the bottom of the filter container.
A
After that, fasten the hoses to the pump (13) and secure with the hose clamps (14).
B
Then hang the pump in the aquarium at the position desired. Cut the hoses to the lengths
desired and connect to the hose connection piece on the filter container head (17).
The EHEIM aquacompact filter offers various ways to customise the flow pattern from the
C
pump as desired. You have the option of using either the nozzle (5) or the nozzle tube (2).
Be sure you connect hose L from the pump to hose connection piece L on the filter con-
tainer head. The same applies correspondingly to hose R.
Note: Check all the hose connections at regular intervals for correct fitting.
Putting into operation
Mind the minimum water level for the pump so that it can operate properly.
D
E
EHEIM aquacompact External Filters already contain all the filtering materials needed for
their operation (EHEIM
Model: See type plate on pump casing
+ +
media). Before use, rinse the EHEIM SUBSTRATpro filtering
4
max.
100 cm
▼
geprüfte
Sicherheit