Transport And Storage; Transport; Storage; Technical Data - Graf Optimax-XXL Instrucciones De Montaje

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3.1

Transport

The filters must be secured to prevent shifting and falling during transport. If the filters are secured for
transport using tension belts, make sure that the filters remain undamaged.
Stress caused by impacts must be avoided. The filters must in no event be rolled or dragged across the
ground.
3.2

Storage

If the filters require intermediate storage, this must be done on suitable level ground. During storage,
damage caused by environmental or external factors must be avoided.
Height
Inlet view
Description
Max. roof area
Max. throughflow
Water yield
Sprayer through flow
Length
Width
Height
Height offset/inlet and outlet
Inlet connection
Sewer connection
Filtered water connection
Cleaning unit connection
* Dimensioning according to DIN 1986 for horizontal pipelines for a max. partial pipe filling of 0,7 at 1,5%
slope
info@graf.info
www.graf.info
3.

Transport and storage

4.

Technical data

Length
Side view cross-section
DN 300 (12")
connection
3.000 m² (32.300 ft
100 l/sec (27 US gal./sec)*
over 95%
80 l/min (21 US gal./min)
1125 mm (44,3")
675 mm (26,5")
770 mm (30,7")
45 mm (1,7")
DN 300 (12")
DN 300 (12")
DN 300 (12")
1"
10 / 22
DN 400 (16")
connection
2
)
6.000 m² (65.000 ft
200 l/sec (53 US gal./sec)*
over 95%
80 l/min (21 US gal./min)
1125 mm (44,3")
675 mm (26,5")
770 mm (30,7")
45 mm (1,7")
DN 400 (16")
DN 400 (16")
DN 400 (16")
1"
Width
Outlet view
2
)

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

340096

Tabla de contenido