appliance. The gap between the switch contacts
must be no less than 3 mm.
• Switch off the appliance at the installation's main
switch: a) if the appliance does not function
correctly; b) before cleaning the outside of the
appliance; c) if the appliance is not to be used for
any length of time.
• The room must have an adequate source of
replacement air for this appliance to function
effectively. Moreover, if there is any non-sealed
combustion based appliance such as a water
heater, gas stove, etc. in the same room, air
replacement must be sufficient for all appliances
to work effectively together.
• The appliance must either exhaust directly to the
outside or into a short duct (max 400 mm in
length to ensure certified performance). Efficiency
losses will occur if the appliance is installed in
ducting subject to any appreciable back pressure.
• The appliance cannot be used to control
activation of water heaters, room heaters, etc. nor
must it be connected to the hot air ducts used by
other appliances.
• The air to be extracted from the room must be
clean (i.e. free of grease, soot, chemical and
* (or an authorised Service Centre if you live outside the UK or Ireland)

MODELS

A. Standard Model
This model is operated by switching it on by means
of the power switch.
B. Timer Model
This model is equipped with a timer factory-set for
a minimum operating time of 3 minutes. The timer
may be set at between 3 and 20 minutes by
adjusting the trimmer (see fig. 14A). The appliance
switches on automatically a few seconds after the
light is switched on and continues to run for the set
time after the light is switched off.
corrosive agents, and explosive or flammable
mixtures) and must not exceed a temperature of
50°C (122°F).
• Keep the appliance's inlet and outlet grilles free to
ensure an optimum flow of air.
• Install the appliance so that the impeller is
inaccessible from the air outlet side as verified by
contact with the Test Finger, in compliance with
the current safety regulations. If this is not
possible, the relevant protection accessory must
be installed.
T HCS Model: do not cover or obstruct the
humidity sensor grille (fig.19).
N.B.
If the appliance is installed across a wall and
wall tiling, to ensure correct operation a spacer
must be fitted to compensate for any
differences in the surface levels.
The appliance can also be installed on a ceiling.
For ceiling mounting a special gasket contained
in a kit to be ordered separately must be used in
order to maintain a protection rating of IPX4.
Do not install the appliance on a ceiling without
first inserting the relevant gasket.
C. C. T HCS LL Model
This model has a preset humidity sensing circuit
that switches it on when the relative humidity
exceeds 65%. The circuit is also equipped with a
timer that can be set at between 3 and 20 minutes
by adjusting the trimmer (see fig. 14B). The unit
switches on automatically a few seconds after the
light is switched on and continues to run for the
preset period of time after the light is switched off.