Kohler K-682 Guia De Instalacion página 21

Ocultar thumbs Ver también para K-682:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Troubleshooting (cont.)
Troubleshooting Table
Symptoms
10. Water leaking from the
valve.
CAUTION: Risk of
personal injury or
product damage. Turn off
the main power and
water supply.
11. Hot water only, the valve
shuts down.
Kohler Co.
Probable Cause
A. Connections are not secure.
B. Seals are worn or damaged.
C. Internal leak.
A. Hot and cold lines are reversed.
21
Recommended Action
A. Check all connections. Make
adjustments as needed.
B. Order a seal service pack and
replace all seals.
C. Unit requires overhaul. Contact
your Kohler Co. authorized service
representative.
A. Switch hot and cold water supply
connections. Verify the hot water
supply is connected to the inlet
marked "H" and the cold water
supply is connected to the inlet
marked "C."
1043183-2-E

Publicidad

Tabla de contenido
loading

Tabla de contenido