M.-Nr. 10504670
Danger due to incorrectly carried out service and repair work
There is a risk of serious damage, injury and even death if service and repair work is carried out incorrectly.
– Service and repair work should only be carried out by a suitably qualified electrician with specialist training,
knowledge and experience.
– All appropriate safety regulations must be taken into account.
– First read the Technical Service Documentation (TSD), then commence work.
Risk of injury due to sharp edges!
CAUTION
There may be a risk of injury due to sharp edges.
Risk of injury due to sharp edges!
A
Protective gloves should be worn and the edge protection, Mat. no. 05057680, should be used.
UO8005-8010 fitting
Fixing plinth to floor
A
Position the plinth on the floor.
A
Mark the hole positions.
A
Drill 12 mm dia. holes in the marked positions approx. 65 mm deep.
A
Insert plugs (5) in the holes, see Fig. 1.
A
Fasten the plinth to the floor with the hexagonal-head wood screws (1), 8.4 washers (2) and 38 x 4 washers (3), see
Fig. 1.
A
At the same time use the underlays (4) as necessary to compensate for unevenness in the floor, see Fig. 1.
Place the machine on the plinth
A
Fit the clamps on the plinth and fasten them in the appropriate holes (1), see Fig. 2.
Tip
The arrow (2) embossed on the top of the plinth points to the front, see Fig. 2.
A
Secure each clamp to the plinth with an M6 x 30 bolt (1), two galvanised B6.4 washers (2) and an M6 nut (3). Do not
tighten the nuts yet, see Fig. 3.
A
Place the machine on the plinth.
A
Slide the clamps over the machine feet, see Fig. 3.
A
Tighten the M6 nuts.
A
In each case, fit a second M6 nut (4) to counter the first nut, see Fig. 3.
UO8005-47 fitting
Fixing plinth to floor
A
Position the plinth on the floor.
A
Mark the hole positions.
A
Drill 12 mm dia. holes in the marked positions approx. 65 mm deep.
A
Insert plugs (5) in the holes, see Fig. 4.
A
Fasten the plinth to the floor with the hexagonal-head wood screws (1), 8.4 washers (2) and 38 x 4 washers (3), see
Fig. 4.
A
At the same time use the underlays (4) as necessary to compensate for unevenness in the floor, see Fig. 4.
Diese Unterlagen dürfen ohne unsere Genehmigung weder vervielfältigt noch Dritten zugänglich gemacht werden. Eigentumsrechte vorbehalten.
Umbau- und Montageanweisung
19 von 58