6. DMX CONNECTION AND DMX PROTOCOL
DMX addressing
•
The device is controlled by universal DMX 512
protocol, DMX address is the start channel
used to receive instructions from the exter-
nal controller. For independent control, each
fixture must be assigned its unique address
control channels. For example, this device has
four channel modes: 22/51/19/21, if we set
the mode at standard 22 channels mode, and
there are several models need to be inde-
pendently controlled, we just simply address
DMX Receive
Slave Receive
Slave Receive 1,2,3
Sequence
Master / Alone
Music
Master / Alone
Chase Part 1
Chase 1 ~ 8 Chase 1
Chase Part 2
Chase 1 ~ 8 Chase 2
Chase Part 3
Chase 1 ~ 8 Chase 3
Chase 1
Chase Test
:
Step 01
Chase 8
Step 64
Edit Scene 001
Pan,Tilt,......
~ Edit Scene 250
--Fade Time--
--Secne Time--
DMX Input
ScXX=>ScXX
•
•
•
=SCxxx
=SCxxx
=xxx
=xxx
=xxx
first fixture at 1, and second fixture at 23, third
one at 45, etc.
If the devices have the same address, they will
behave synchronically.
DMX addressing is limited, don't set the address
so high that without enough control channels
for the fixtures.
Display is flashing when no DMX signal is re-
ceived.
DMX Receive
Choose slave posi-
tion
Run Sequence
Music mode
Select and run auto
program
Test
Beginning scene
Ending scene
Input manual scene
Modify manually
fading time
Modify manually
scene time
Input scene from
exterior controller
Auto Input scenes
P. 11