Safety Notes
Gloves should be worn during installation to prevent crushing and cutting
injuries.
The shower system may only be used for bathing, hygienic and body cleaning
purposes.
Children as well as adults with physical, mental and/or sensoric impairments
must not use this product without proper supervision. Persons under the influ-
ence of alcohol or drugs are prohibited from using this product.
The hot and cold supplies must be of equal pressures.
Installation Instructions
• Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
• The pipes and the fixture must be installed, flushed and tested as per the applica-
ble standards.
• The plumbing codes applicable in the respective countries must be oberserved.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Rate of flow by 0,3 MPa:
1 Consumer
2 Consumer
Thermal disinfection:
The product is exclusively designed for drinking water!
Safety against backflow
Special information for UK (see page 36)
Fault
Insufficient water
Crossflow, hot water being forced into cold water pipe,
or vice versa, when mixer is closed
Spout temperature does not correspond with tempera-
ture set
Temperature regulation not possible
Safety stop button not operating
4
English
max. 1 MPa
0,15 - 0,6 MPa
1,6 MPa
max. 80°C
65°C
approx. 44 l/min
approx. 55 l/min
max. 70°C / 4 min
Cause
- Supply pressure inadequate
- Regulator filter dirty
- Shower filter seal dirty
- contaminated dirt catch sieve in front of the backflow
stop
- Backflow preventers dirty or leaking
- Thermostat has not been adjusted
- Hot water temperature too low
- Temperature regulator dirty or calcified
- For new installations: basic body incorrectly con-
nected (should be: cold right, hot left) or installed with
180º rotation
- Spring defective
- push button calcified / contaminated
Assembly see page 31
Symbol description
Do not use silicone containing acetic acid!
Safety Function (see page 32)
The desired maximum temperature for example max. 42º C can be pre-
set thanks to the safety function.
Adjustment (see page 32)
After the installation, the output temperature of the thermostat must be
checked. A correction is necessary if the temperature measured at the
output differs from the temperature set on the thermostat.
Maintenance (see page 34)
• To guarantee the smooth running of the thermostat, it is necessary
from time to time to turn the thermostat from total hot to total cold.
• The mixer is equipped with check valves. The check valves must be
checked regularly according to DIN EN 1717 in accordance with
national or regional regulations (at least once a year).
Dimensions (see page 33)
Operation (see page 33)
Spare parts (see page 35)
Cleaning
see enclosed brochure
Test certificate (see page 40)
Remedy
- Check water pressure (If a pump has been installed
check to see if the pump is working).
- Clean filter in front of the mixer and on the MTC-
thermo cartridge
- Clean filter seal between shower and hose
- Clean filters
- Clean backflow preventers, exchange if necessary
- Adjust thermostat
- Increase hot water temperature to 42 ºC to 65 ºC
- Clean temperature regulator, exchange if necessary
- change connections
- Clean spring and/or button, exchange if necessary