Operation
TO ADJUST CALIBRATION
IMPORTANT: Always obtain three (3) test
results from the grain elevator for the sample be-
ing compared. Average these three (3)
results. Compare this average with the
average of three (3) tests by the
moisture tester.
1. The corn scale can be individually adjusted up
to 5.0% by increments of 0.1% to more closely
match the results of an elevator tester.
2. Test the corn selected, using the sample you
wish to adjust to. Once valid moisture
appears, press the CAL button (A).
NOTE:
Calibration of corn cannot be performed unless a valid
moisture test has been performed.
3. Once CAL button (A) is pressed, tester will now display the obtained moisture
reading and the current offset applied to that moisture range.
4. Press the UP arrow (B) to raise the adjustment amount or press the DOWN arrow
(C) to lower. The tester will add or subtract up to 5.0% by increments of 0.1% to
the current moisture range.
5. After the adjustment amount has been selected, press the CAL button (A) to return
to corn tester mode.
NOTE:
Adjustment can NOT be made to factory calibration to produce
moisture readings in a tester that shows "LESS THAN 5%" or
"TOO WET" readings.
IMPORTANT: This tester incorporates single-point calibration for corn. Therefore,
once a valid test is taken and an adjustment is made, the adjustment will only affect
the moisture range of the sample tested.
CORN
NOTE: If grain temperature is 40˚F (4˚C) or below, or 110˚F (43˚C) or above, and the grain moisture is
near either the high or the low limit of the unit (listed above), the tester is programmed to close
down its range of operating limits.
8
DISPLAY READING
MOISTURE LIMIT GUIDELINES
(Specifications and design subject to change without notice)
........................5.0% ......................21.0%
Moisture Range
Low Limit
Moisture Range
High Limit