Descargar Imprimir esta página

GYS M3 AUTO Manual Del Usuario página 16

Ocultar thumbs Ver también para M3 GYS AUTO:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27
SPOOL GUN (OPTION)
Spool gun description and functionning
• The spool gun torch must be plugged into machine's torch connector.
• The spool gun torch works either in "Manual" mode or in "Synergic" mode.
• In"Manual" or "Synergic" mode, only the wire speed adjustment knob on the torch is active (the wire speed potentiometer
of the machine is not active).
• "Synergic" mode:
- Put the wire speed knob of the Spool gun torch in the middle then adjust if necessary.
- For more information refer to the paragraph "Synergic" mode.
Assembly process
Reel :
- Open the lid
- Remove the reel holding nut (2) (NB. reversed screw thread)
- Tighten the locknut (3) to bulge the reel axle (do not tighten too much)
- Fit the wire reel
- To fit the wire in the rollers, apply pressure on the "roller tension adjusting screw"
- Pull out the wire of the torch by winding up the reel
- Pull out the torch
- Plug the power connector of the spool gun on the torch connector 1
- Plug the control connector of the spool gun
- Put the switch on the torch 1 position
DUTY CYCLE AND WELDING ENVIRONMENT
- The welding unit described has a "constant current" output type. Its duty cycle following the norm EN60974-1 (at 40°C
on a 10mn cycle) is indicated in the table below:
X/60974-
1 à 40°C(T
cycle=10min)
M3 GYS AUTO
Note: The warming test was done at room temperature and the duty cycle at 40°C were determinated by simulation.
- These are A-class devices. They are designed to be used in an industrial or professional environment. In a different
environment, it can be difficult to ensure electromagnetic compatibility, due to conducted disturbances as well as
radiation.
- The M1, T1 and T3 comply with IEC 61000-3-12, if the power of the short-circuit Ssc is equal to or greater than 1.8MVA
at the interface between the machine and the mains. It is the responsibility of the installer or user of the equipment to
ensure if necessary by consulting the power supply user, that the equipment is only connected to a power supply where
the power of short-circuit ssc is equal to or greater than 1.8MVA.
ADVICE AND THERMAL PROTECTION
- Respect the basic rules of welding.
- Ensure the machine's vents are clear enabling air circulation.
- Leave the device plugged after welding to enable cooling.
- Thermal protection: The light turns on and the cooling time is a couple of minute depending on the room temperature.
M3 GYS AUTO
1- Lid opening/closing button
2- Reel holding nut
3- Reel locknut (do not tighten too much)
4- Rollers tension adjusting screw
5- Wire speed adjusting knob
I max
60%(T cycle=10min)
15% à 140A
100%(T cycle=10min)
80A
EN
60A
16

Publicidad