15. INSTALL BLOWER (PKEX22 SERIES ONLY)
WARNING
!
Do not plug the two cords together.
To install, see instructions packed with blower.
Once the blower is installed, plug the blower cord (B) into the female receptacle
and the power supply cord (A) onto the male connector inside the power pack.
16. REINSTALL HYBRID BAFFLE FILTERS
Remove protective plastic film covering hybrid baffle filters before installing them.
 Insert one end of the hybrid baffle
filter into the back channel of the
power pack.
 Raise the other end toward the
inside and insert in the front
channel of the power pack.
Replacement filters are available
from your dealer. See label inside
power pack for part number.
17. CALIBRATE IQ BLOWER SYSTEM™ (PK22 SERIES ONLY)
After the power pack is installed and wired, engage the calibration process (our Guaranteed
Performance System Technology to ensure full-rated airflow is being delivered). Prior to
calibration, ensure that all filters, light bulbs and duct system are installed.
C
P
ALIBRATION
ROCESS
Hold the calibration button for 3 seconds; calibration button will light up and stay on
for up to 13 minutes. The blower will start and begin the calibration process. When
calibration is complete, one of two things will occur:
A. The blower turns off and calibration button light stays on = Successful calibration.
Press the button to turn off the LED. NOTE: The LED will also turn off if you select any
blower speed on the control.
B. The blower turns off and calibration button light blinks continuously = Too much
restriction in the ductwork is preventing the IQ Blower System™ from achieving the
rated airflow. The blower is automatically set to maximum intensity.
NOTE: Common items that cause restrictions: restricted damper flap (backdraft
damper, wall cap, roof cap), too many elbows, duct size less than 80% of hood outlet, poor transition, use of flex ducting and/or
crushed ducting.
Three options are available if your power pack system has too much restriction:
1. Accept airflow as is. Press the calibration button to accept airflow as is. The IQ Blower System™ is now configured to its highest possible
performance. The blinking calibration light goes out. NOTE: The LED will also turn off if you select any blower speed on the control.
2. Correct duct restriction, clear the original calibration data, and repeat the calibration process.
a. Correct the duct restriction.
b. Clear the original calibration data by holding calibration button for 10 seconds. The light will blink 3 times to confirm and the blower
configuration will go back to default settings.
c. Repeat calibration process from the beginning.
3. Clear calibration data to reset power pack to default factory settings and achieve standard high pressure blower performance by holding
calibration button for 10 seconds. The light will blink 3 times to confirm and the blower configuration will go back to default settings.
CAUTION
1
HD0501
10
B
HE0078
2
C
ALIBRATION BUTTON
C
ALIBRATION LIGHT
HC0066